High Performance Enterprise Class Storage Using NVMe
The Viking Enterprise Solutions (VES) NSS2560 storage server offers fifty-six 2.5” NVMe drives (U.2) combined with two server modules. Each server has access to all fifty-six NVMe drives with dual port devices. The NSS2560 is a dense HA solution that provides a tremendous amount of storage in a small package.

The enclosure contains two hotswappable server modules. Each of the servers is a dual socket Skylake server with two x16 PCIe add in card slots, and up to 8 DIMMs per CPU. The NSS2560 fits into an industry standard 19” wide by 1.2m deep rack. Its flexible configuration allows it to be deployed in a variety of applications.

Extremely dense 2U package with 56 NVMe drives and two servers.

Datasheets
PRODUCT BRIEF INQUIRY

Features

  • 56 Hot-pluggable NVMe drives
  • HA system with each server able to access all of the drives
  • Management interface to control drive access & provisioning
  • Hot-pluggable servers, power supplies, fans & drives
  • SFF-8639, PCIe Gen 3 NVMe (U.2) drive support (up to 18W per drive)
  • Single and dual port NVMe drive support. Single port drives are only seen by one server
  • Resilient environmental specification with up to a 35C ambient inlet
  • Provisions for battery backup/super caps for NVDIMMs
  • Standard chassis customization & branding available
  • Upgradeable to Skylake server modules
AC Power Hot-Swappable Components Firmware Drive Partitioning
Nominal Input Range:100 - 240VAC Two Server Modules IPMI and Redfish management Management software controls the visibility & access to each drive
Input frequency: 47-64 Hz Four fans CLI and GUI control for drive management & status of the enclosure One port of a single port drive can be hidden for data protection
Power Source: dual redundant 3kwatts (4 total 1.5kwatt power supplies) Four AC to DC power supplies − Each supply provides up to 1500W of power
Input current: 15 amps max @ 180V AC per power supply Two independent AC power inputs
Inrush current: 40 amps peak per power supply 56 NVMe drives (hot pluggable)
Maximum system continuous DC output power rating: 3kwatts
2U Enclosure Failure Notifications Performance Capacity
Dimensions: 3.2 in. H x 17.6 in. W x 37.4 in. D (87 mm H x 448 mm W x 951 mm D) Status & fault LEDs for the enclosure, drives & servers Up to 64 GB/s bandwidth between both servers 56-drive capacity
Weight with drives: 85 lbs (39 kg) max U.2 PCIe 3.0 NVMe drives
Railkit with CMA Failure Notifications Dual port drive
Up to 18W per drive
Operating Environment Non-Operating Environment Drive Partitioning Safety Standards
Temperature: 5° to 35°C Temperature: -40° to 60°C Controlled by the management software through the 1Gbe link UL 60950
Relative humidity: 20% to 80% (non-condensing) Relative humidity: 10% to 90% (non-condensing) CSA 22.2-950
Altitude: -200 to 10,000 ft Altitude: -200 to 40,000 ft
Shock: 3G at 11ms, 1/2 sine wave pulse Shock: 10G at 11ms, 1/2 sine wave pulse
Vibration: 0.10G at 5 Hz to 500 Hz Vibration: 0.5G at 5 Hz to 500 Hz
Quality Standards Servers Electromagnetic Emissions & Immunity Standards Monitoring & Reporting
Manufactured under an ISO 9002 registered quality system One or two Server modules CE Mark Monitoring for temperature, power, cooling (including fan speed control), drives, as well as error rates & quality of service
Intel Broadwell processors EN55022: 2010 Reporting of all serial number, part number, & revisions of the server modules, power supplies, drives & chassis
Upgradeable to Intel Skylake processors EN61000 3-2:2014
Each server takes 2 x16 PCIe add in cards EN61000 3-2:2013
FCC Class A
Canadian IECS-003