Viking Technology
Menu

NDS-4900

High Performance Enterprise Class High Density 94 drive Storage Server
The Viking Enterprise Solutions (VES) NDS-4900 High Density Storage Server combines 90 3.5” hard disk drives (HDD) with four 2.5” solid state disks (SSD) at 12Gb/s. There is no need to sacrifice HDD slots to incorporate SSDs for caching.

The enclosure contains either two single or two dual processor Haswell/Broadwell servers. Each server can power 2x 145W processors and 2x full spec PCIe cards. The servers are specifically designed for data throughput. The VES NDS-4900 Storage Server offers best-in-class performance and capacity, space-saving density, “green” energy efficiency and 24×7 high-availability redundancy of key components.

The NDS-4900 fits into an industry standard 19” wide by 1.2m deep rack. Its flexible configuration allows it to be deployed in a variety of applications.

Datasheets
PRODUCT BRIEF INQUIRY

Features

  • Operation with either single or dual servers or I/O controllers for redundant failover
  • Multiple drive partitioning / split-bus zoning modes
  • Hot-pluggable servers or I/O controller(s), fan modules, & redundant, high efficiency, advanced power modules
  • SFF-8644, 12 Gb/s, SAS 3.0 host and expansion ports or expansion of up to 100 Gb/s network interface with server modules
  • Flexibility to choose SAS or SATA drives to achieve the right performance, reliability & price
  • Modular design increases product configuration flexibility
  • Standard chassis customization & branding available
  • SAS point-to-point connectivity isolates drive failures, increasing reliability & fault tolerance & improving performance
  • SAS daisy-chain expansion to additional storage arrays & other SFF-8644 SAS-compliant host/expansion ports, or add-on PCIe 3.0 HBA
Host/Expansion Interfaces Capacity Hot-Swappable Components Firmware
One or two Haswell/Broadwell server modules 94-drive capacity per 4U enclosure Two Haswell/Broadwell servers or two JBOD I/O modules IPMI 2.0 baseboard management controller
Single or dual 145W processors 90 LFF drive slots in main bay Two AC to DC power modules SCSI Enclosure Services (SES) 3.0-based firmware
Up to 3 PCIe 3.0 slots per server module Four SFF drive slots in rear of enclosure Each module includes two 1,600 watt power supplies
Two x8 PCIe 3.0 All drives 12Gb/s One +5V regulator per power module provides hard drive power
One x16 PCIe 3.0 (with dual CPU only) Optional supercap / battery modules are incorporated into the power modules
Two M.2 boot drives Four independent AC power inputs
NVDIMM support Up to 90 Drives in main bay
Supercap power fail support Up to four SSDs in rear bays
One or two VES SAS 3.0 JBOD I/O controller modules, each with six 12Gb/sec SAS 3.0 SFF-8644 ports
4U Rackmount Enclosure Failure Notifications Disk Drives AC Power
Dimensions: 7.0 in. H x 16.5 in. W x 37.8 in. D (17.7 cm H x 41.9 cm W x 96.0 cm D) IPMI fault reporting 94 independent point-to-point connections to each SAS or SATA disk drive with dual-port access and failover by each controller to each drive Input voltage: 180-264V AC
SCSI Enclosure Services (SES-3.0) over in-band interface and via LEDs SCSI Enclosure Services (SES-3.0) over in-band interface and via LEDs 90 3.5” drives in main drive bay Input frequency: 47-63 Hz
Four 2.5” drive bays at rear of enclosure Power supplies per power module: 2
SATA drives require optional 2:1 Active MUX (interposer card) Input current: 9.4 amps max @ 200V AC per power supply
Form factor: 3.5” & 2.5” SAS, SATA & SSD drives Inrush current: 40 amps peak per power supply
Rotational speeds up to 15K RPM Maximum system continuous DC output power rating: 3200 watts
Interface: 12Gb/6Gb/3Gb SAS; 6Gb/3Gb SATA
Drive Partitioning/Split-Bus Zoning Monitoring and Reporting Performance Operating Environment
Controller module can be zoned in two pre-defined zoning schemes for I/O modules & two for server modules Monitoring for temperature, power, cooling (including fan speed control), disk drives, server & I/O module(s), as well as error rates & quality of service Up to 48 GB/s (sustained reads) using 12 Gb/s SSD drives Temperature: 5° to 35°C
Additional zoning schemes can be developed upon request In-band reporting of all serial number, part number, & revisions of the server & I/O modules, power modules, drives, & chassis Up to 38 GB/s (sustained reads) using 6 Gb/s SSD drives Relative humidity: 20% to 80% (non-condensing)
Altitude: -200 to 10,000 feet
Shock: 3G at 11ms, 1/2 sine wave pulse
Vibration: 0.10G at 5 Hz to 500 Hz
Acoustics (declared sound power): 8.4 Bels with server Modules 7.7 Bels with I/O modules; at idle/active operation tested to ISO 7779
Non-Operating Environment Electromagnetic Emissions & Immunity Standards Safety Standards Quality Standards Environment Protection
Temperature: -40° to 60°C CE Mark UL 60950 Manufactured under an ISO 9002 registered quality system RoHS & WEEE compliant
Relative humidity: 10% to 90% (non-condensing) EN55022: 2010 CSA 22.2-950
Altitude: -200 to 40,000 ft EN61000 3-2:2014
Shock: 10G at 11ms, 1/2 sine wave pulse EN61000 3-2:2013
Vibration: 0.5G at 5 Hz to 500 Hz FCC Class A
Canadian IECS-003